ODVF Round Outdoor Vapor Fireplace

Three circular mist-fire sizes for outdoor feature projects.

Compare ODVF350, ODVF550 and ODVF750 using the current dimension drawings and outdoor manual. Plan the top flange, body, cut-out, usable water volume and drainage together before building a circular fire table or terrace feature.

350 / 550 / 750 mmTop-flange diameters
2.6 / 7.7 / 11.7 LWater at the high level
IP24Enclosure rating stated in the outdoor manual
SEFIRE ODVF350 circular water vapor fireplace with illuminated mist effect, illustrative visual

Updated October 27, 2026: dimensions follow the three supplied drawings; water volumes and operating requirements follow the English outdoor manual V2.

Outdoor protection: the manual specifies IP24 splash protection. The appliance is not immersion-proof or water-jet-proof; retain the supplied feet and provide drainage.

Direct Answer

Round outdoor mist flames, with a defined installation plan.

ODVF is SEFIRE's circular outdoor decorative water vapor fireplace family. Water mist and lighting create the flame-like effect without burning ethanol, gas or wood. The outdoor manual describes local buttons, remote and app control, automatic filling and draining, and an IP24 enclosure.

The 350, 550 and 750 mm model sizes describe the top flange, not the cylindrical body or installation opening. The current drawing height is 176 mm; keep the supplied feet fitted and allow for their actual projection beneath the body.

Current Model Data

Compare the flange, body and water volumes.

Dimensions and calculated cut-out references (mm)
ModelTop flangeBody diameter DDrawing heightCut-out D + 5
ODVF350350 mm330 mm176 mm335 mm
ODVF550550 mm528 mm176 mm533 mm
ODVF750750 mm728 mm176 mm733 mm

Dimensions read from the supplied 350 / 550 / 750 drawings. The 335 / 533 / 733 mm cut-outs are calculated from the manual's D + 5 mm rule. Verify the actual body, flange support and connections before fabrication. The raised top feature is shown as 15 mm; the drawings do not specify the fitted foot projection.

Water volumes at the operating levels

Approximate liters, rounded to one decimal place
ModelLow level (35 mm)High level (70 mm)Usable atomizing water
ODVF3500.6 L2.6 L2.1 L
ODVF5503.7 L7.7 L4.0 L
ODVF7505.7 L11.7 L6.0 L

Read these columns separately: usable atomizing water is the high-level volume minus the low-level volume, calculated before rounding. Each displayed value is rounded independently to one decimal place. These volumes are reference data, not manual filling quantities; let automatic filling stop at the correct level.

SEFIRE ODVF350 circular water vapor fireplace with illuminated mist effect, illustrative visual

Compact

ODVF350

Balcony and compact patio concepts. Confirm exposure, drainage and access for the complete installation.

High-level water
2.6 L
Usable water
2.1 L
Body diameter
330 mm
SEFIRE ODVF550 circular water vapor fireplace with illuminated mist effect, illustrative visual

Mid-size

ODVF550

Garden and terrace concepts. Confirm exposure, drainage and access for the complete installation.

High-level water
7.7 L
Usable water
4.0 L
Body diameter
528 mm
SEFIRE ODVF750 circular water vapor fireplace with illuminated mist effect, illustrative visual

Large

ODVF750

Hotel and large courtyard concepts. Confirm exposure, drainage and access for the complete installation.

High-level water
11.7 L
Usable water
6.0 L
Body diameter
728 mm

Mist-effect illustrations supplied for ODVF350, ODVF550 and ODVF750. Appearance varies with lighting, airflow and operating settings.

Cut-out & Support

Measure the body below the flange and retain every foot.

  • Opening diameter: body diameter D + 5 mm in total, approximately 2.5 mm on each side when centered. Do not add 5 mm to the top-flange diameter.
  • Recess depth: H + F + 10-20 mm, where H is the actual body height below the flange and F is the supplied feet's projection below the body. Measure F on the appliance; no universal finished recess depth is given.
  • Support the top flange securely around the rim on a stable, level structure capable of supporting the appliance with a full tank.
  • No separate enclosure air inlet is required for this round model, but every factory-made appliance opening and the mist outlet must remain clear.
  • Reserve extra space for hoses, cables, inspection and complete removal. Provide a drainage route so rainwater or leakage cannot pool under the body.

Outdoor Protection

IP24 splash protection with drainage and sealed connections.

The supplied outdoor manual specifies IP24 for the enclosure: protection against solid objects 12.5 mm and larger and splashing water from any direction. This is not dust-tight protection and does not permit immersion, water jets or standing water. Keep the body, supplied waterproof power supply and all electrical connections out of pooled water.

  • Keep the factory-supplied feet / pads fitted; do not remove or bypass feet, seals or electrical protection.
  • Use the supplied power supply and the voltage / electrical configuration on the delivered rating label. The supplied documents do not provide a model-by-model power table.
  • A qualified electrician must install any cable extension using suitable outdoor cable, sealed waterproof joints, cable glands and strain relief. Insulating tape alone is not a waterproof joint.
  • Keep connections accessible for inspection, above possible standing water and protected from mechanical damage. Isolate power before wiring or servicing.
  • Do not wash the appliance with a hose or pressure washer. If a connection becomes wet internally or the unit is immersed, isolate power safely and arrange inspection before reuse.

IP24 is the enclosure rating stated in the supplied product manual, not a claim of independent testing or a rating for the complete project enclosure. Confirm order-specific documents and site requirements with the installer.

Water, Controls & Maintenance

Fill and drain in standby; service the atomizing heads every three months.

Automatic filling

Keep power connected with the flame effect OFF. Connect the supplied hose to IN with its free end in clean water. Hold UP (Flame +) for more than 5 seconds; wait for filling to stop automatically before starting the effect. Never add alcohol, fragrance or combustible liquid.

Automatic draining

With the effect OFF, connect the hose to OUT and secure its end in a suitable container or drain. Hold UP and DOWN together for more than 5 seconds. Monitor discharge to prevent overflow.

Permanent water connection

Where fitted, have a qualified installer connect the designated automatic-fill connection through the supplied filter. Supply pressure must be below 0.07 MPa (0.7 bar); do not connect a higher-pressure supply directly.

Remote and app control

The manual includes local button, remote and E-SMART FIRE app instructions for effect level, color, brightness and timer. Sound controls apply only when the optional sound function is fitted. Confirm RS485 or other integration options for the ordered configuration.

Scheduled transducer replacement

Have qualified service personnel replace the atomizing heads every three months with specified parts. Cleaning does not replace this schedule. Restore seals, refill normally and check for leakage and correct mist output after service.

Water quality and winter storage

Use clean, decalcified water; distilled water reduces mineral deposits. Before freezing conditions or extended non-use, drain in standby, isolate the water supply and disconnect power. Do not operate with frozen water.

Dimension Sketches & Manual

Dimensioned isometric line sketches.

Black-and-white product line sketches show the top-flange diameter, body diameter and body height directly on each view. Factory title blocks, logos and unrelated annotations are omitted. All dimensions are in millimeters.

Round Outdoor Vapor Fireplace - English Manual V29 pages · PDF · approximately 643 KB. Includes IP24 precautions, feet and cut-outs, water volumes, controls and the three-month atomizing-head replacement schedule.

Body height excludes the raised top feature and fitted feet. These dimensioned sketches are for product reference; confirm the delivered appliance and approved installation drawing before fabrication.

Quotation Details

Confirm the delivered configuration before ordering.

Provide the ODVF model, finish, site exposure, electrical supply, water and drain arrangements, controls, destination and quantity. Confirm gross weight, crate size, lead time, integration options and warranty on the current quotation. The supplied manual does not establish a guaranteed runtime; do not calculate operating hours from rounded water volumes alone.

Technical FAQ

Questions before specifying ODVF.

Which ODVF dimensions should I use for an opening?

The 350, 550 and 750 mm sizes refer to the top flange. The current drawings show body diameters of 330, 528 and 728 mm and a drawing height of 176 mm. The manual specifies a cut-out diameter of body D + 5 mm, giving 335, 533 and 733 mm for planning; confirm the delivered appliance before fabrication. Keep the supplied feet fitted and allow H + F + 10-20 mm recess depth plus service space.

What are the current ODVF water volumes?

For ODVF350, ODVF550 and ODVF750, water volume at the 70 mm high level is approximately 2.6, 7.7 and 11.7 L; usable atomizing water is approximately 2.1, 4.0 and 6.0 L. These are different quantities. Values are rounded to one decimal place; use automatic filling rather than adding these quantities manually.

What does IP24 mean for this outdoor fireplace?

The supplied outdoor manual specifies IP24 for the enclosure: splash protection, not immersion or water-jet protection. Keep the body, supplied power supply and connections out of standing water. Retain all supplied feet, provide drainage and have cable extensions installed with sealed waterproof joints by a qualified electrician.

How often should the atomizing heads be replaced?

The outdoor manual requires replacement of the atomizing heads every three months by qualified service personnel. Cleaning does not replace this scheduled change. Drain, isolate the water supply and disconnect power before freezing conditions or extended non-use.

Does ODVF use real fire or provide a guaranteed runtime?

No fuel is burned: water mist and lighting create the decorative effect. The supplied outdoor manual does not establish runtime or model-specific electrical ratings. Follow the delivered rating label and confirmed specification; water volume alone is not a runtime guarantee.